These instructions are a general guide only; instructions on flipside of access cover of your hot water system should be used.

  1. Remove the access cover
  2. Turn the gas control knob to the off position
  3. Wait 5 minutes to allow any build-up of gas to escape. If you can smell gas, stop. If you do not smell gas proceed to step 4.
  4. Turn the knob to the pilot position.
  5. Press the knob fully down and after 30 seconds, whilst keeping the knob pressed down, repeatedly press the igniter button until the pilot flame ignites.
    WARNING: Keep your face and body clear of the combustion chamber opening while pressing the ignite button.
    NOTE: It is not possible to press down the knob fully if the gas control has activated its safety shut-off feature. In this case, wait 60 seconds for the gas control to reset.
  6. Keep the knob pressed down for at least 40 seconds or until you have a strong pilot flame.
  7. Release the knob and check the pilot is still alight. The pilot can be checked by looking through the large opening below the gas control.
  8. If the pilot has failed to light or has not remained alight, turn the gas control knob to the off position 1. Wait 5 minutes for any unburnt gas to disperse and then begin at step 4 again.
    WARNING: Failure to wait 5 minutes may result in a fire or explosion.
  9. When the pilot flame remains alight with the gas control knob released , turn the knob anticlockwise to the number setting, the higher the number the hotter the water – this will also depend on what brand of hot water system you have.
  10. Replace access cover.